Scag Power Equipment SWZ52V-19KAI Manuel D’Utilisation

Page de 92
29
R
Section 7
ENGINE AIR CLEANER
7.6 
A. CLEANING AND/OR REPLACING AIR 
CLEANER ELEMENT
For  any  air  cleaner,  the  operating  environment  dictates 
the air cleaner service periods. Inspect and clean the air 
cleaner element after every 100 hours of operation or bi-
weekly, whichever occurs first and replace the element if 
required.
- NOTE -
In extremely dusty conditions it may be necessary 
to check the element once or twice daily to prevent 
engine damage.
Remove the air cleaner cover. Set aside.
1. 
Remove the air cleaner and inspect.
2. 
Clean or replace the air cleaner and foam 
3. 
pre-cleaner as recommended by the engine 
manufacturer.
Replace the air cleaner cover and secure.
4. 
BATTERY - ELECTRIC START MODELS
7.7 
 WARNING
Lead-acid  batteries  produce  flammable  and 
explosive gases. To avoid personal injury when 
checking, testing or charging batteries, DO NOT 
use smoking materials near batteries. Keep arcs, 
sparks and flames away from batteries. Provide 
proper ventilation and wear safety glasses.
 WARNING
Battery posts, terminals, and related accessories 
contain  lead  and  lead  compounds,  chemicals 
known to cause cancer and reproductive harm. 
Wash hands after handling.
 WARNING
Electric  storage  battery  fluid  contains  sulfuric 
acid  which  is  POISON  and  can  cause  SEvERE 
CHEMICAL  BURNS.  Avoid  contact  of  fluid  with 
eyes, skin, or clothing. Use proper protective gear 
when handling batteries. DO NOT tip any battery 
beyond 45° angle in any direction. If fluid contact 
does occur, follow first aid suggestions below.
BATTERY ELECTROLYTE FIRST AID
External Contact — Flush with water.
Eyes — Flush with water for at least 15 minutes 
and get medical attention immediately.
Internal — Drink large quantities of water. Follow 
with Milk Of Magnesia, beaten egg, or vegetable 
oil. Get medical attention immediately. In case of 
internal contact, DO NOT give fluids that would 
induce vomiting.
A. CHARGING THE BATTERY
Refer  to  the  battery  charger’s  manual  for  specific 
instructions.
Under normal conditions the engine’s alternator will have 
no problem keeping a charge on the battery. If the battery 
has been completely discharged for a long period of time, 
the alternator may not be able to recharge the battery, and 
a battery charger will be required.
DO NOT charge a frozen battery. It may explode and cause 
injury. Let the battery warm before attaching a charger.
Whenever  possible,  remove  the  battery  from  the  mower 
before charging and make sure the electrolyte covers the 
plates in all cells.
 WARNING
BATTERIES  PRODUCE  ExPLOSIvE  GASES. 
Charge the battery in a well ventilated space so 
gases produced while charging can dissipate.