Multiquip BS46HLE Manuel D’Utilisation

Page de 68
BS46H SeRIeS WaLK-BeHIND TROWeL • OpeRaTION aND paRTS maNUaL — Rev. #2 (10/15/13) — page 23
5.  Grasp the starter grip (Figure 24) and slowly pull it out. 
The resistance becomes the hardest at a certain 
position, corresponding to the compression point. Pull 
the starter grip briskly and smoothly for starting.
Figure 24. Starter Grip
6.  If the engine has started, slowly return the choke lever  
(Figure 25) to the 
cLOSEd position. If the engine has 
not started repeat steps 1 through 5.
Figure 25. Choke Lever Closed
7.  Before the trowel is placed into operation, run the 
engine for several minutes. Check for fuel leaks, and 
noises that would associate with a loose guard ring 
and/or covers.
operation
Testing the centrifugal Safety Stop Switch
1.  With the engine running at idle, place the safety stop 
switch lever in the 
"Off" position (Figure 26). Verify 
that the engine shuts off. If the engine continues to run, 
replace centrifugal safety stop switch.
Figure 26. Testing Safety Stop Switch
2. 
Before performing this test, clear the area around the 
trowel. Make sure it is free of debris and objects. Move 
the safety stop switch lever to the 
"ON" position, restart 
the engine and let idle.
Stand behind the handle and spin the handle to the right, 
simulating a runaway situation. (See Figure 27).  
Centrifugal force should throw the safety switch outward 
to the "
Off" position thus shutting off the engine.
Figure 27. Testing Safety Stop Switch 
Runaway Situation
OFF
KE
EP CLEAR