LUBRICATION
Oil Level 
Check the oil level in the engine when the machine is 
standing level and the engine is stopped. 
Remove the dipstick, wipe it clean, and screw it back 
into place. 
Take the dipstick out again and read the oil level. The 
oil level shall lie between the markings on the dipstick. 
If the level is approaching the “ADD” mark, fill the oil to 
the “FULL” mark on the dipstick. Never fill above the 
“FULL” mark. 
The oil is filled through the hole for the dipstick. 
API class SF, SG, SH, SJ or higher must be used 
Synthetic oil SAE 5W-30 or 10W30 is recommended 
at all temperatures. Mineral oil SAE 5W-30, 10W30 
can be used between 0 °F/-18 °C and 40 °F/+5 °C. At 
temperature above 40 °F/+5 °C single grade SAE 30 
must be used. 
The engine holds 1.5 quarts (1.4 liters) of oil excluding 
the filter; including the filter 1.6 quarts (1.5 liters). 
8011-500
Remove the dipstick
8009-159
Dipstick markings
8011-739-1
Kohler oil filter
8011-739-1
Briggs & Stratton oil filter
Changing the Oil Filter
1.   Drain the engine oil following the procedure 
described in Engine Oil/ Change Engine Oil 
section. 
2.   Remove the oil filter. If necessary, use a filter 
remover. 
3.   Wipe new, clean engine oil on the seal of the new 
filter. 
4.   Mount the filter by hand with + ¾ turn. 
5.   Run the engine warm, to check that there are no 
leaks around the oil filter seal.
Transmission
The transmission is maintenance free and there is no 
need for level checks or oil changes. If a leak occurs, 
replace the unit or contact your Husqvarna dealer.