Operating 
Your Spa
www.calspas.com
25
on, the equipment will automatically turn off after 15 
minutes.
Light
Press the “LIGHT” button to turn the spa light on and 
off and to shift between dim and bright settings if your 
light is dimmable. On dim, the control panel will show 
the center circle plus one quarter of the light beams. 
Half of the light beams will show on medium bright-
ness, and all of the light beams will show on bright.
Invert
Press  the  “INVERT”  button  to  change  the  numbers 
in  the  display  to  read  upside  down.    Another  press 
returns the display to the right-side-up position. This 
enables you to read the display while you are in the 
spa.
Locking the Panel
To lock the panel:
Press “TIME”, “JETS 1”, and the “UP” button within 
• 
three seconds. When locked, the panel will display 
“LOCK”. All buttons are frozen except the “TIME” 
button.
To unlock the panel:
Press “TIME”, “JETS 1” then the “DOWN” button 
• 
within three seconds.
Setting the Temperature Lock
To activate the temperature lock:
Press the “UP” or “DOWN” button, “TIME”, “JETS 
• 
1”, then the “UP” button within three seconds. The 
panel will display “TEMP LOCK” when the set tem-
perature is locked.
To unlock the set temperature:
Press the “UP” or “DOWN” button, “TIME”, “JETS 
• 
1”, and then the “DOWN” button.
Circulation Pump
This is an optional feature. The circulation pump will 
come  on  when  the  system  is  checking  temperature, 
during filter cycles, during freeze conditions, or when 
another pump is on.
Preset Filter Cycles
There are two filter cycles per day. The start and end 
times  of  each  cycle  are  programmable.  To  program, 
set the time as instructed above, then press “MODE/
PROG” to advance to the next setting  (or to exit after 
the  last  setting).  The  default  filter  cycles  are  as  fol-
lows:
The  first  filter  cycle  is  automatically  activated  at 
• 
8:00 AM and operates the pump until 10:00 AM. 
The “FILTER 1” indicator icon will light when filter 
1 is running.
The second filter cycle is automatically activated 
• 
at 8:00 PM and operates the pump until 10:00 PM. 
The “FILTER 2” indicator icon will light when filter 
2 is running.
The pump and the ozone generator will run during fil-
tration. At the start of each filter cycle, the blower will 
run on highest speed for 30 seconds to clean out the 
air channels. The lowest speed of pump 2 and pump 
3 will run for five minutes. In the event of power loss 
or shut down, the time of day will need to be reset for 
filter cycles to run according to your desired program-
ming.
Clean-up Cycle
When the pump or blower is turned on by a button 
press,  a  clean-up  cycle  begins  30  minutes  after  the 
pump or blower is turned off or times out. The pump 
and the ozone generator will run for one hour.
Ozone
This  is  an  optional  feature.  On  most  systems,  the 
ozone generator (if installed) runs during filter cycles 
(except when pump 1 is operating at high speed on a 
non-circ system) and during clean-up cycles. On some 
systems, the ozone generator operates whenever the 
pump runs. If your system is configured with the op-
tional ozone disable feature, the ozone generator will 
turn off for one hour any time a function button (“JETS 
1”, “JETS 2”, “OPTION” etc.) is pressed.
Freeze Protection
If  the  temperature  sensors  detect  a  drop  to  44°F 
within  the  heater,  the  pump  automatically  activates 
to  provide  freeze  protection.  The  equipment  stays 
on  until  four  minutes  after  the  sensors  detect  that 
the  spa  temperature  has  risen  to  45°F  or  higher.  In 
colder  climates,  an  optional  additional  freeze  sensor 
may be added to protect against freeze conditions that 
may not be sensed by the standard sensors. Auxiliary 
freeze sensor protection acts similarly except with the 
temperature thresholds determined by the switch and 
without a four-minute delay in turnoff.