SECTION 10: W
IRING
25 of 47
10.5 Electrical Connection to the Heater
IMPORTANT: Junction box is not provided with heater. 
Conduit can also be attached directly to heater with wire junction made within the heater cabinet.
BX Connector
Junction Box
Flexible Conduit
Burner
Connect wires together
with suitable approved
wire connectors.
Green to Ground
White to L2
Black to L1
L1
L2
Ground
Black
White
Green