Maintenance
CLEAN SPARK ARRESTOR SCREEN 
(50 STATE)
The engine exhaust muffler has a spark arrestor screen. Inspect and 
clean  the  screen  every  50  hours  of  operation  or  once  each  year, 
whichever comes first.
Clean and inspect the spark arrestor as follows:
•  Remove the screen retainer by removing the retainer clamp.
•  Slide the spark arrestor screen out from the muffler outlet tube.
•  Inspect  screen  and  replace  if  torn,  perforated  or  otherwise 
damaged.  Do  NOT  use  a  defective  screen.  If  screen  is  not 
damaged, clean with a commercial solvent.
•  Replace the screen and retainer and secure with retainer clamp.
Figure 12 - Spark Arrestor Screen