ga6HB/6HeB 60 hz gENERATOR • OpERATiON ANd pARTs mANuAl — REv. #0 (03/13/14) — pAgE 25
generator storage
For storage of the generating set for over 30 days, the 
following is required:
 
„
Drain the fuel tank completely, or add STA-BIL to the 
fuel.
 
„
Run the engine until the gasoline in the carburetor is 
completely consumed.
 
„
Completely drain the oil from the crankcase and refill 
with fresh oil.
 
„
Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into 
the cylinder and crank slowly to distribute the oil.
 
„
Slowly rotate the engine a few times with the starter rope 
and install a new plug.
 
„
Pull out the starter rope slowly and stop at the 
compression point.
 
„
Clean all external parts of the generating set with a 
cloth.
 
„
Cover the generating set and store in a clean, dry 
place.
PRePaRaTion foR lonG TeRm sToRaGe