Generac Power Systems 5415 Manuel D’Utilisation

Page de 82
Section 6
TROUBLESHOOTING FLOWCHARTS
Page 35
REPLACE 
PRINTED CIRCUIT 
BOARD
INSTALL NEW
7.5 AMP FUSE
CHECK THAT FUSE 
HOLDER IS NOT 
GROUNDED
CHECK WIRE 15 
FOR SHORT TO 
GROUND
CHECK REMOTE 
HARNESS WIRE 15 
FOR SHORT TO 
GROUND
CHECK WIRE 56 
FOR SHORT TO 
GROUND
CHECK WIRE 90 
FOR SHORT TO 
GROUND
CHECK CHOKE 
SOLENOID AND 
STARTER 
CONTACTOR 
RELAY
 STARTER CONTACTOR 
RELAY PIN LOCATION 
J1-1 TEST TO GROUND
 CHOKE SOLENOID 
PIN LOCATION J1-2 
TEST TO GROUND
REMOVE WIRE 15 
FROM JI HARNESS 
CONNECTOR.
DOES FUSE BLOW?
(SEE NOTE A)
PERFORM RESISTANCE TESTS ON FUEL PUMP, FUEL SOLENOID, 
CHOKE HEATER AND REMOTE HARNESS WIRE 14 (SEE * BELOW).
ALSO CHECK WIRE 14 TO EACH COMPONENT FOR SHORT TO GROUND.   
* CHECK FOR CONTINUITY TO FRAME GROUND. CONNECT ONE TEST 
LEAD TO THE POSITIVE WIRE FOR EACH COMPONENT. CONNECT THE 
OTHER TEST LEAD TO FRAME GROUND. RESISTANCE SHOULD BE 
MEASURED. IF CONTINUITY “0” IS MEASURED TO GROUND, THAT 
COMPONENT OR WIRE IS SHORTED.
ALSO, REFER TO THE INDIVIDUAL TESTS FOR EACH COMPONENT IN 
SECTION 7, UNDER “PROCEDURE – SHORT TO GROUND”.
NOTE A:
Disconnect harness from engine controller 
circuit board.
Gently bend red tabs outward and remove red 
plastic pin guide.
Using a small flathead screwdriver, slide black 
retainer tabs out away from Wire 15 pin 
(orange).
Gently push pin out of harness and pull wire 
out from back of plug, noting it’s location for 
reinstallation later.
Replace red pin guide and plug J1 harness 
back into engine controller circuit board.
Replace fuse.
If fuse does not blow, replace engine controller 
circuit board.
If fuse still blows, continue to next section of 
Problem 10 flow chart.
DISCONNECT JI HARNESS 
FROM ENGINE CONTROL-
LER CIRCUIT BOARD AND 
CHECK WIRE 14 FOR 
SHORT TO GROUND.
IS CONTINUITY PRESENT?
FUSE BLOWS UPON 
INSTALLATION
FUSE IS GOOD BUT 
BLOWS WHEN START-
STOP SWITCH IS 
PRESSED
REPAIR OR 
REPLACE 
COMPONENT 
OR WIRE
REPLACE COMPONENT OR WIRE
PASS
YES
YES
FAIL
FAIL
FAIL
NO
NO
REPLACE HOLDER
Problem 10 – 7.5A (F1) Fuse Blowing