Generac Power Systems 5412 Manuel D’Utilisation

Page de 82
Section 7
DIAGNOSTIC TESTS
4
0
Figure 7-10. – Brush Leads
TEST 9 – CHECk BRUSHES & SLIP RINgS
DISCUSSION:
Brushes and slip rings are made of special materials 
that will provide hundreds of hours of service with little 
wear. However, when the generator has been idle for 
some time, an oxide film can develop on the slip rings. 
This film acts as an insulator and impedes the flow of 
excitation current to the Rotor.
If Test  4  resulted  in  less  than  one-half  rated  output 
voltage,  it  is  possible  that  the  brushes  and  slip  rings 
are at fault.
PROCEDURE:
1.  Gain access to the brushes and slip rings.
2.  Remove Wire 4 from the positive (+) brush termi-
nal.
3.  Remove the ground wire (Wire 0) from the nega-
tive (-) brush.
4.  Remove the brush holder, with brushes.
5.  Inspect the brushes for excessive wear, damage, 
cracks, chipping, etc.
6.  Inspect the brush holder, replace if damaged.
7.  Inspect the slip rings.
a. If slip rings appear dull or tarnished they may be 
cleaned  and  polished  with  fine  sandpaper.  DO 
NOT  USE  ANY  METALLIC  GRIT  TO  CLEAN 
SLIP RINGS. (A 400 grit wet sandpaper is rec-
ommended).
b. After cleaning slip rings, blow away any sandpa-
per residue.
RESULTS:
1.  Replace  bad  brushes.  Clean  slip  rings,  if  neces-
sary.
2.  If brushes and rings are good, go to Test 10.
TEST 10 – CHECk ROTOR ASSEMBLY
DISCUSSION:
During the “Test 4 – Fixed Excitation Test,” if AC out-
put  voltage  did  not  come  up  to  about  one-half  rated 
volts, one possible cause might be a defective Rotor. 
The Rotor can be tested for an open or shorted condi-
tion using a volt-ohm-milliammeter (VOM).
Also see Chapter Three, “INSULATION RESISTANCE 
TESTS”.
PROCEDURE:
Gain access to the brushes and slip rings. Disconnect 
Wire 4 and Wire 0 from their respective brushes and 
remove the brush holder. Then, test the Rotor as fol-
lows:
1.  Set a VOM to its “Rx1” scale and zero the meter. 
2.  Connect  the  positive  (+)  meter  test  lead  to  the 
positive  (+)  slip  ring  (nearest  the  Rotor  bearing). 
Connect  the  common  (-)  test  lead  to  the  nega-
tive (-) slip ring. Read the resistance of the Rotor 
windings, in OHMS.
ROTOR RESISTANCE 
*
MODEL
OHMS
RV45 5410/5411
13.4
Ω
RV55 5412/5413
14.88
Ω
RV65 5414/5415
10.81
Ω
 
*  Resistance  values  In  ohms  at  20°  C.  (68°  F.). 
Actual  readings  may  vary  depending  on  ambient 
temperature.  A  tolerance  of  plus  or  minus  5%  is 
allowed.
3.  Set  the VOM  to  its  “Rx1  k”  or  “Rx10,000”  scale 
and zero the meter.
4.  Connect  the  positive  (+)  meter  test  lead  to  the 
positive (+) slip ring, the common (-) test lead to a 
clean frame ground (such as the Rotor shaft). The 
meter should read “Infinity”.
RESULTS:
1.  Replace the Rotor if it fails the test. 
2.  If  Rotor  checks  good,  perform  “Insulation 
Resistance Test,” on Page 14.
Page 42