Cleveland Range inverter Manuel D’Utilisation

Page de 119
Chapter 5 - MODBUS-RTU Communication 
 
 
84
< FU2 Group > 
Parameter 
address 
Parameter 
Code 
Description 
Default 
value 
Max. value 
Min value 
Unit 
Note 
630A 
FU2 #10 
Jump freq 
 
 
630B 
FU2 #11 
Jump lo 1 
FU2-12 
0.01Hz 
 
630C 
FU2#12 Jump 
Hi 
1  0  FU1-20  FU2-11 0.01Hz   
630D 
FU2 #13 
Jump lo 2 
FU2-14 
0.01Hz 
 
630E 
FU2 #14 
jump Hi 2 
FU1-20 
FU2-13 
0.01Hz 
 
630F 
FU2 #15 
jump lo 3 
FU2-16 
0.01Hz 
 
6310 
FU2 #16 
jump Hi 3 
FU1-20 
FU2-15 
0.01Hz 
 
6314 
FU2 #20 
Power-on run 
 
 
6315 
FU2 #21 
RST restart 
 
 
6316 FU2 
#22  ssMode  0000  1111 
0000 
 
 
6317 FU2 
#23 ssStallPerc 180  200 
80 
 
6318 
FU2 #24 
SS P-Gain 
100 
9999 
 
 
6319 
FU2 #25 
SS I-Gain 
1000 
9999 
 
 
631A 
FU2 #26 
Retry number 
10 
 
 
631B 
FU2 #27 
Retry delay 
10 
600 
0.1sec 
 
631E 
FU2 #30 
Motor select 
 
 
631F 
FU2 #31 
Pole number 
12 
 
 
6320 FU2 
#32 Rated-Slip  *  1000 
0  0.01Hz   
6321 
FU2 
#33 
Rated-Curr * 999  1 0.1A  
6322 
FU2 
#34 
Noload-Curr 
* 999  1 0.1A  
6324 FU2 
#36 Efficiency  * 
100 
50 
 
6325 FU2 
#37 Inertiarate  0 
 
 
6327 
FU2 #39 
Carrier freq 
30 
100 
10 
0.1kHZ 
 
6328 
FU2 #40 
Control mode 
 
 
6332 
FU2 #50 
PID F/B 
 
 
6333 
FU2 #51 
PID P-gain 
3000 
9999 
 
 
6334 
FU2 #52 
PID I-time 
300 
9999 
 
 
6335 
FU2 #53 
PID D-time 
9999 
 
 
6336 
FU2 #54 
PID limit 
5000 
FU1-20 
0.01Hz 
 
6346 
FU2 #70 
Acc/Dec freq 
 
 
6347 
FU2 #71 
Time scale 
 
 
6348 
FU2 #72 
PowerOn disp 
13 
 
 
6349 
FU2 #73 
User disp 
 
 
634A 
FU2 #74 
RPM factor 
100 
1000 
 
634B 
FU2#75 
DB 
Mode 
2 2  0   
634C 
FU2#76 
DB % ED 
10 
30 
 
634F 
FU2 #79 
S/W version 
 
 
 
 
 
6351 
FU2 #81 
2nd Acc time 
50 
9999 
0.1sec 
 
6352 
FU2 #82 
2nd Dec time 
100 
9999 
0.1sec 
 
6353 
FU2 #83 
2nd BaseFreq 
5000 
FU1-20 
3000 
0.01Hz