Specifications 
Dimensions, (L, W, H) and Weight: 
HD Venue Base Station  
 
16.9‖ (43.03 cm) x 8.0‖ (20.32 cm) x 1.7‖ (4.42 cm), 2.0 lbs (5.45 kg) 
HD Charger Base     
 
 
4.6‖ (11.75 cm) x 3.125‖ (7.9 cm) x 1.0‖ (2.54 cm), 0.325 lbs (0.147 kg) 
Wireless Microphones   
 
Wearable: 0.9‖ (2.3 cm) x 0.8‖ (2.0 cm) x 2.6‖ (6.6 cm), 0.05 lb (0.02 kg) 
   
 
 
 
 
TableTop: 1.5‖ (3.8 cm) x 0.8‖ (2.0 cm) x 3.3‖ (8.4 cm), 0.05 lb (0.02 kg) 
   
 
 
 
 
XLR Adapter: 0.9‖ (2.3 cm) x 0.8‖ (2.0 cm) x 4.0‖ (10.2 cm), 0.05 lb (0.02 kg) 
   
 
 
 
 
Countryman Adapter:  
1.5‖ (3.8 cm) x 0.8‖ (2.0 cm) x 3.3‖ (8.4 cm), 0.05 lb (0.02 kg) 
Shipping Weight 
 
 
 
2.0 lbs (5.45 kg) 
 
Radio Frequency
:  
01-HDVENU 
 
 
 
 
1.92 to 1.93 GHz (UPCS North America) 
(and other 01-HD* products)  
 
 
 
03-HDVENUEU  
 
 
 
1.88 to 1.90 GHz (DECT EU) 
(and other EU products)  
 
03-HDVENUCN  
 
 
 
1.90 to 1.92 GHz 
(and other CN products)  
03-HDVENUJP   
 
 
 
1.895 to 1.903 GHz 
(and other JP products) 
 
Maximum Output 
 
15.7dBm  37.15mW 
Channel spacing:  
 
1.728 MHz 
Modulation:  
 
 
GFSK 
Class:    
 
 
ISM 
 
Connectors:    
 
Base Station Audio   
 
 
¼‖ and XLR Balanced (2 In & 2 Out) 
Firmware Port    
 
 
 
Mini-USB 
Charger Base   
 
 
 
DC power input port, Proprietary 4 pin microphone charge jacks 
Microphone 
 
 
 
 
Proprietary 4 pin charge plugs, 2.5mm mono earplug port (16 ohm) 
 
Power Requirements
: 
Base Station  
 
 
 
 
5V DC, 1 Amp (switching power supply varies by country) 
Charger Base     
 
 
 
5V DC, 2 Amps (switching power supply varies by country) 
Range:
 
300
‘ (91 meters) approx. (actual range depends on RF signal absorption, reflection, and 
interference
 
Battery:
 
 
 
 
 
Lithium Polymer, Up to 8 hours approx. talk time 
Charge Time:
  
 
 
 
2 hours approx. 
Security:
 
 
 
 
 
128-bit DSAA (DECT Standard Authentication Algorithm) authentication, 64 bit DECT 
Standard Cipher 
Audio Bandwidth:
 
 
 
50 
– 14000 Hz 
 
Included Accessories:
    
1 Earpiece with inline volume control and 1 Lanyard per Wearable Microphone 
 
Environmental Requirements:
 
Temperature 
 
 
 
 
40° to 105° F (5° to 40° C) operating 
Humidity 
 
 
 
 
20% to 85%