Furuno FI-506 Manuel D’Utilisation

Page de 62
FI-506 RUDDER 
 
 
E7271S01A 
SP-
3
SPECIFICATIONS OF 
FI-506 RUDDER 
 
1 GENERAL 
1.1 Display 
Analog 
1.2  Analog Meter Display Range 
 ±40° 
1.3  Analog Meter Display Accuracy    ±5° 
1.4  I/O Port 
NMEA 2000, 2 ports 
 
JUNCTION BOX (OPTION) 
2.1  No. of I/O ports 
 
NMEA 2000 Device 
6 ports 
 
NMEA 2000 Backbone 
2 ports 
 
3    POWER SUPPLY AND POWER CONSUMPTION 
3.1  Display Unit 
12 VDC, less than 0.1 A 
3.2 Junction 
Box 
12 VDC, less than 1 A, max. 2A connectable A 
 
4 ENVIRONMENTAL 
CONDITIONS 
4.1  Useable Temperature Range 
 -15°C - +55°C 
4.2  Relative Humidity 
Less than 95% (+40°C) 
4.3 Waterproofing 
 
 Display 
Unit 
IP56 
 Junction 
Box 
IPX0 
4.4  Vibration 
- 2 Hz-5 Hz and up to 13.2 Hz with an   
 
 
excursion of ±1 mm ±10% (7 m/s
2
   
 
 
maximum acceleration at 13.2 Hz); 
 
 
 
- above 13.2 Hz and up to 100 Hz with   
 
 
 
constant maximum acceleration of 7 m/s
2
 
 
5 COATING 
COLOR 
5.1 Display 
Unit 
N2.5 
5.2 Junction 
Box 
N2.5