Topcon GTS-822A Manuel D’Utilisation

Page de 144
2-2   
   2 PREPARATION FOR MEASUREMENT
2.2
Setting Instrument Up For Measurement
Mount the instrument to the tripod. Level and center the instrument precisely to insure the best 
performance. Use tripods with a tripod screw of 5/8 in. diameter and 11 threads per inch, such as the 
Type E TOPCON wide- frame wooden tripod.
1. Setting up the Tripod
First, extend the extension legs to suitable lengths 
and tighten the screws on their midsections.
2. Attaching the Instrument on the Tripod 
Head 
Place the instrument carefully on the tripod head 
and slide the instrument by loosening the tripod 
screw. If the plumb bob is positioned right over the 
center of the point, slightly tighten the tripod 
screw.
3. Roughly Leveling the Instrument by Using the Circular 
Level
1
Turn the leveling screws A and B to move the 
bubble in the circular level. The bubble is now 
located on a line perpendicular to a line 
running through the centers of the two leveling 
screws being adjusted.
2
Turn the leveling screw C to bring the bubble 
to the center of the circular level.
4.  Centering by Using the Plate Level
1
Rotate the instrument horizontally by using 
the Horizontal motion/clamp screw and place 
the plate level parallel with the line connecting 
leveling screws A and B, and then bring the 
bubble to the center of the plate level by 
turning leveling screws A and B. 
2
Rotate the instrument 90° (100g) around its 
vertical axis and turn the remaining leveling 
screw or C to center the bubble once more.
3
Repeat the procedures 1 and 2 for each 90°  
(100g) rotation of the instrument and check 
whether the bubble is correctly centered for all 
four points.
5. Centering by Using the Optical Plummet 
Telescope
Adjust the eyepiece of the optical plummet 
telescope to your eyesight.
Slide the instrument by loosening the tripod 
screw, place the point on the center mark, and 
then tighten the tripod screw. Sliding the 
instrument carefully not to rotate that allows you 
to get the least dislocation of the bubble.
6. Completely Leveling the Instrument
Leveling the instrument precisely in a similar way 
to 4. Rotate the instrument and check to see that 
the bubble is in the center of the plate level 
regardless of telescope direction, then tighten the 
tripod screw hard.
Leveling 
screw A
Leveling screw C
Leveling screw B
Leveling 
screw A
Leveling 
screw B
90
Leveling screw C
Point
Center mark
Reference: Leveling and Centering the Instrument