4-13
   4 STANDARD MEASUREMENT MODE
4.3.3 Execution of Coordinate Measuring
Measure the coordinates by entering the instrument height and prism height, coordinates of unknown 
point will be measured directly.
l
l
When setting the instrument height and prism height, see Section 4.3.2“Setting of the Instrument 
Height / Prism Height” .
l
The coordinates of the unknown point are calculated as shown below and displayed:
Coordinates of occupied point : (N
0
, E
0
, Z
0
)
Instrument height
: Inst.h
Prism height
: R.h
Vertical distance (Relative elevation) : z
Coordinates of the center of the prism,
originated from the center point of the instrument
: (n,e,z)
Coordinates of unknown point  : (N
1
, E
1
, Z
1
)
N
= N
+ n
E
= E
+ e
Z
= Z
+ Inst.h + z  -  P.h
Confirm the angle measurement mode.
Operating procedure
Operation
Display
1
Set coordinates values of occupied point and 
instrument/prism height. *1)
2
Set the direction angle of known point A. *2)
Set 
direction 
angle
3
Collimate target B.
Collimate
4
Press [F3](NEZ) key.*3)
Measuring starts.
[F3]
Origin (o, o, o)
Occupied point (No, Eo, Zo)
Center point of the instrument
(No, Eo, Zo + Inst.h)
Coordinates of the center of the prism, originated from the center point of the instrument (n,e,z)
Unknown point
(N
1
, E
1
, Z
1
)
 V :  90
°10'20" 
 HR: 120
°30'40" 
                    
                     
 SD  HD  NEZ  0SET  HOLD P1
 N :        
   <
 E :                PSM   0.0
 Z :                PPM   0.0
                     (m) *F.R
MEAS  MODE  VH   SD   HD  P1
↓