   18 ERROR DISPLAYS
18
ERROR DISPLAYS
l
If error still persist after attempting to clear them, contact your local Topcon dealer or Topcon head 
office.
Error code
Description
Countermeasures
Backup 
battery 
empty
Displayed when built in battery for memory 
back up is empty.
Contact your dealer or Topcon.
W/C OVER
Displayed when measurement carried out 
within ±9
°
 from zenith or nadir at the Earth 
curvature and refraction correction mode is 
ON.
Set correction for refraction and earth 
curvature mode OFF or measure out of ±9
°
  
from the zenith or Nadir.
H angle 
measuring 
error
Displayed when the instrument rotated too 
fast or any abnormality occurs in angle 
measuring system .
The instrument will return to previous mode 
automatically.
V angle 
measuring 
error
Displayed when the telescope rotated too fast 
or any abnormality occurs in angle measuring 
system.
The instrument will return to previous mode 
automatically.
E31
Displayed when the unit of the angle at the 
recall mode is different from the unit stored in 
setting mode.
Make the unit in same unit system.
E35
Displayed when REM measurement carried 
out to the range from zenith or nadir ± 6
°
 .
Operate in the range out of ± 6
°
 from the 
zenith or nadir.
E36
Displayed when the N.E coordinates are set 
same as the instrument coordinate in setting 
direction angle or lay out mode.
Set except the instrument coordinate value.
E60’s
Any abnormality occurs with EDM (distance 
measuring system).
Repair is required.
E71
Displayed when Vertical angle 0 position is 
set with incorrect procedure.
Confirm the procedure and readjust.
E72
Displayed when Vertical angle -position is 
adjusted in wrong position.
Confirm the procedure and readjust
E73
The instrument was not leveled when Vertical 
angle 0-position is adjusted.
Level the instrument then carry the 
adjustment work.
E81
E82
Mainly at the time data transmission between 
GTS-820 series and external instrument.
Press [F1](EXIT) key, and confirm the 
connection cables are correct.
Other
E80‘s
Data transmission error between internal 
P.C.B.‘s.
Restart and confirm the operation procedure 
is correct.
E90‘s
Abnormality in internal memory system.
Repair is required.
E300‘s
Abnormality in tracking system.
Repair is required.
E600‘s
Abnormality in angle measuring system.
If this error code continues to display, repair is 
required.
E700‘s
Abnormality in angle measuring system.
If this error code continues to display, repair is 
required.
E800‘s
In the self checking mode, vibration is too big. Get rid of the Vibration