Topcon GTS-823A Manuel D’Utilisation

Page de 144
1-5   
   1   NOMENCLATURE AND FUNCTIONS
1.4
Function Key (Soft Key)
The Soft Key Functions are labeled on the bottom of display. Soft Key functions are different for each 
measurement.
Page
Display
Soft
key
Function
Angle
measuring
SD
F1
Slope distance measuring mode.
HD
F2
Horizontal distance measuring mode.
NEZ
F3
Coordinate distance measuring mode.
0SET
F4
Set horizontal angle to 0°00'00".
HOLD
F5
Horizontal angle hold.
TURN
F1
Turns the instrument to required angle automatically.  
HSET
F2
Preset a horizontal angle.
R/L
F3
Changes horizontal angle right or left.
V/%
F4
Changes the display to vertical angle or percent of grade.
TILT
F5
Sets the tilt function, ON/OFF.
If ON,  the display shows tilt correction value.
Horizontal distance measuring
Coordinate measuring
Angle measuring
Slope distance measuring
 
 
 
 
 TURN  HT  MEAN        P2
 
 
 
 
 REC  SO   MEAN        P2
 
 
 
 
 TURN  SO  MEAN  m/ft  P2
 
                   
                    
 TURN HSET R/L  V/% TILT P2
Soft keys
    
                     
                        
V :  87°55'45"5
HR: 180°44'12"5
 
 
  SD   HD   NEZ  0SET HOLD   
P1
[F1]
[F2]
[F3]
[F4]
[F5]
[F6]
 
 V :  87°55'45"5 
 HR: 180°44'12"5     
                      
                      
 SD  HD  NEZ  0SET  HOLD P1
 
 V :  90 10'20"5 
 HR: 120 30'40"5  PSM   0.0
 HD:              PPM   0.0
 VD:               (m)  F.R
 MEAS  MODE  VH  SD  NEZ  P1
 
 V :  90°10'20"5 
 HR: 120°30'40"5  PSM  0.0
 SD:              PPM  0.0
                  (m)  F.R
 MEAS  MODE  VH  HD  NEZ  P1
 
 N :  12345.6789
 E : -12345.6789   PSM  0.0
 Z :     10.1234   PPM  0.0
                    (m) F.R
 MEAS MODE VH  SD  HD  P1