2-6   
   2 PREPARATION FOR MEASUREMENT
2.6
Vertical and Horizontal Angle Tilt Correction
When the tilt sensors are activated, automatic correction of vertical and horizontal angle for 
mislevelment is displayed.
To ensure a precise angle measurement, tilt sensors must be turned on. The display can also be used 
to fine level the instrument. If the (TILT OVER) display appears the instrument is out of automatic 
compensation range and must be leveled manually.
l
GTS-820A series compensates both the vertical angle and the horizontal angle readings due to 
inclination of the standing axis in the X and Y directions.
l
For more information about dual axis compensation, see Chapter  “APPENDIX” “Dual Axis 
Compensation”
.
l
The display of Vertical or Horizontal angle is unstable when instrument is on an unstable stage or a 
windy day. You can turn off the auto tilt correction function of V/H angle in this case. To set TILT 
correction mode ON/OFF, refer to next page or Chapter 8 “PARAMETERS SETTING MODE”.
VV
WW
XX
SS
PP
OO
TT
QQ
DD
UU
RR
||
Standing axis
Zenith 
Inclination of the standing
axis in the X direction
Standing axis
Zenith 
Inclination of the standing 
axis in the Y direction
Trunnion axis
Horizontal 
When the instrument tilted over correction 
range. 
Rotate the leveling screws and level the 
instrument. 
After leveling (when each axis is within ±1'30"), 
the display returns to the previous mode 
automatically.
X,Y tilt correction range : within ±4'
X:
Y:
X:+0°00'00"
Y:+0°00'00"