Topcon GTS-823A Manuel D’Utilisation

Page de 144
4-3
   4 STANDARD MEASUREMENT MODE
2) Setting a Horizontal Angle from the Keys
Make sure the mode is Angle measurement.
4.1.4 Vertical Angle Percent Grade(%) Mode
Make sure the mode is Angle measurement.
Operating procedure
Operation
Display
1
Collimate the target.
Collimate
2
Press [F6](
) key to get the function as on 
page 2, and press [F2](HSET) key.
3
Input the required horizontal angle.
*1) 
For example:70
°
20'30"
[F6]
[F2]
Input 
value
4
Press [ENT] key. *2)
When completed, normal measuring from the 
required Horizontal angle is possible.
[ENT]
*1)To revise wrong value, move cursor with [F6](BS) key, or input from the beginning by [F1](EXIT) key to 
correct value.
*2)With wrong input value (for example 70'), setting will not be completed. Input again from step 
3
.
Operating procedure
Operation
Display
1
Press [F6](
) key to get the function as on 
page 2.
[F6]
2
Press [F4](V/%) key. *1)
[F4]
*1) Every time pressing the [F4](V/%) key, the display mode switches.
 V :  90
°10'20"  
 HR: 120
°30'40"     
                   
                    
 SD  HD  NEZ  0SET HOLD  P1
TURN HSET  R/L  V/% TILT P2
H-SET
 HR: 
H-SET
 HR:70.203
EXIT                    BS
 V :  90
°10'20"   
 HR:  70
°20'30"    
                   
                    
 SD  HD  NEZ  0SET  HOLD P1
 V :  90
°10'20" 
 HR: 120
°30'40"     
                   
                    
 SD  HD  NEZ  0SET  HOLD  P1
 TURN HSET R/L  V/%  TILT P2
 V%:   -0.30    %
 HR: 120
°30'40"     
                   
                    
 TURN HSET  R/L  V/% TILT P2