Topcon GTS-823A Manuel D’Utilisation

Page de 144
4-10   
   4 STANDARD MEASUREMENT MODE
4.3
COORDINATE MEASUREMENT
4.3.1 Setting Coordinate Values of Occupied Point 
The occupied point coordinates (NEZ) can be preset in the GTS-820A Series to calculate the unknown 
point coordinates. It is possible to retain the occupied coordinates in memory once the power is turned 
OFF if the (NEZ mem) is ON in the Parameter Setting Modes. IF (NEZ mem) is OFF in the Parameter 
Setting Modes, the occupied coordinates will be retained only if you choose (Resume ON) when 
shutting the power OFF.
For instructions on how to select NEZ memory ON/OFF, refer to  Chapter 8 “PARAMETERS SETTING 
MODE” .
Confirm the angle measurement mode.
Operating procedure
Operation
Display
1
Press [F3](NEZ) key.
2
press [F6](
) key to get the function as on 
page 2.
[F3]
[F6]
3
Press [F5](SET) key.
The previous data will be shown.
[F5]
N
E
z
n
e
Prism (n,e,z)
Inst.PointC
Origin(0,0,0)
 V :  90
°10'20"   
 HR: 120
°30'40"      
                    
                     
 SD  HD  NEZ  0SET  HOLD P1
 N :         <
 E :               PSM   0.0
 Z :               PPM   0.0
                    (m) *F.R
MEAS  MODE  VH   SD   HD   P1
 
TURN  HT  MEAN  m/ft SET  P2
Setting occ. point
 N :     12345.6700
 E :         12.3400           
 Z :        10.2300      
EXIT                     BS