Topcon GTS-823A Manuel D’Utilisation

Page de 144
5-3
   5 PROGRAM MODES
5.2
Retaining a Coordinate (STORE- NEZ)
Suppose the instrument P0 moves to P1, P2, P3, etc. and the coordinate at P1, P2, P3 etc., last point 
will be retained in the memory, after moving, as from the origin point.
l
Set the coordinate value of instrument point P
0
 and set the direction angle from instrument point P0 
toward known point A 
.
Operating procedure
Operation
Display
1
Press [F2](STORE) key.
[F2]
2
Press [F1](Store NEZ) key. *1)
[F1]
3
Collimate target P1 prism which the 
instrument moves.
Collimate 
P1
4
Press [F1](MEAS) key.
Measuring will start.
[F1]
Horizontal distance and horizontal angle are 
shown.
Origin (0,0,0)
P
3
P
2
P
1
N
Direction angle
Known point A
E
Inst. point P
0
Programs
F1 BS     p              4/7
F2 STORE  p
F3 REM    p
F4 MLM    p            MORE
Retaining Coordinate
1.Store NEZ
2.Recall NEZ   
Store NEZ
 HR :   120°30'40"          
 HD :              m
MEAS               HT  SET 
Store NEZ
 HR :   100°10'20"          
 HD *       
  <
 m
MEAS                    SET
Store NEZ
 HR :   100°10'20"          
 HD *      123.456 m
MEAS
                
 SET