Topcon GTS-823A Manuel D’Utilisation

Page de 144
8-5   
   8 PARAMETERS SETTING MODE
8.2
Setting Parameters 
8.2.1 Parameters for Measurement and Display
[Example setting]
S/A BUZZER: OFF, Atmospheric pressure: hPa 
Operating procedure
Operation
Display
1
Press the [F6] key from the main menu icons.
[F6]
2
Press the [F1] (Measurement) key.
[F1]
3
Select the menu by pressing [F6](
) key. 
(Example: S/A buzz.))
[F6]
4
Press [F3](
) key, and select OFF.
[F3]
5
Select the atmospheric pressure menu by 
pressing [F6](
) key.
[F6]
6
Press [F4](
) key twice, and select hPa.
[F4]
7
Press [F1](SET) key.
[F1]
8
Press [F5](YES) key. *1)
The display returns main menu.
[F5]
*1)  To cancel the setting, press [F6](NO) key.
Parameters
F1 Measurement
F2 Communication
F3 Password
Parameters (Measurement)       
Ang.Unit [  deg ]  gon  mil
Min.Angl   OFF    [  ON  ]
Tilt     [ OFF ] 1axis  2axis 
SET   EXIT   <-   ->   
↑     ↓
Parameters (Measurement)       
S/A buzz.  OFF  [  ON  ]
W-corr.    OFF  [ 0.14 ] 0.20
N/E/Z mem  OFF  [  ON  ]
 
SET   EXIT   <-   ->   
↑     ↓
Parameters (Measurement)       
S/A buzz.[ OFF  ]  ON  
W-corr.    OFF  [ 0.14 ] 0.20
N/E/Z mem   OFF  [  ON  ]      
 
SET   EXIT   <-   ->   
↑     ↓
Parameters (Measurement)       
Pres.Unit [ mmHg ] inHg   hPa 
R/L Lock  [ OFF  ] ON
m/ftLock  [ OFF  ]  ON         
 
SET   EXIT   <-   ->   
↑     ↓
Parameters (Measurement)       
Pres.Uni  mmHg  inHg   [hPa ] 
R/L Lock  [ OFF  ]  ON
m/ftLock   [ OFF  ]  ON         
 SET   EXIT   <-   ->   
↑     ↓
Parameters (Measurement)       
> Set OK?
                    YES  NO