While your NexStar telescope requires little maintenance, there are a few things to remember that will ensure your telescope 
performs at its best. 
 
C
C
a
a
r
r
e
e
 
 
a
a
n
n
d
d
 
 
C
C
l
l
e
e
a
a
n
n
i
i
n
n
g
g
 
 
o
o
f
f
 
 
t
t
h
h
e
e
 
 
O
O
p
p
t
t
i
i
c
c
s
s
 
 
 
Occasionally, dust and/or moisture may build up on the lens of your telescope.  Special care should be taken when cleaning any 
instrument so as not to damage the optics. 
 
If dust has built up on the optics, remove it with a brush (made of camel’s hair) or a can of pressurized air.  Spray at an angle to 
the lens for approximately two to four seconds.  Then, use an optical cleaning solution and white tissue paper to remove any 
remaining debris.  Apply the solution to the tissue and then apply the tissue paper to the lens.  Low pressure strokes should go 
from the center of the corrector to the outer portion.  Do NOT rub in circles! 
 
You can use a commercially made lens cleaner or mix your own.  A good cleaning solution is isopropyl alcohol mixed with 
distilled water.  The solution should be 60% isopropyl alcohol and 40% distilled water.  Or, liquid dish soap diluted with water (a 
couple of drops per one quart of water) can be used. 
 
To minimize the need to clean your telescope, replace all lens covers once you have finished using it. This will prevent 
contaminants from entering the optical tube. 
 
C
C
o
o
l
l
l
l
i
i
m
m
a
a
t
t
i
i
o
o
n
n
 
 
(For NexStar 114 and 130) 
 
The optical performance of your NexStar telescope is directly related to 
its collimation, that is the alignment of its optical system.  Your NexStar 
was collimated at the factory after it was completely assembled. 
However, if the telescope is dropped or jarred severely during transport, 
it may have to be collimated.  The NexStar 60, 80 and 102 are refractor 
type telescopes that have fixed optical systems that should not come out 
of collimation. The NexStar 114 and 130, however has three collimation 
screws that can be used to adjust the alignment of the primary mirror.  
 
To check if your telescope is in collimation the following diagram will 
help you.  If you look into the eyepiece adapter (without an eyepiece) at 
the top of the focuser, this is what you should see.  If the reflection of 
your eye is off center, then collimation is necessary.  
 
Adjustments to the collimation of the telescope can be made by turning 
the collimation adjustment knobs located at the rear of the optical tube. 
First loosen the three Phillips head screws on the rear cell of the tube.  
Turn each collimation knobs, one at a time, until the reflected image of 
your eye in the secondary mirror is centered in the primary mirror.  
Once the telescope is collimated, tighten the Phillips head screws until 
you feel a slight resistance. Do not over tighten the screw. 
If your telescope is out of collimation, the best way to re-collimate it is 
with a good collimation tool. Celestron offers a Newtonian Collimation Tool (#94183) with detailed instructions that make it an 
easy chore. 
 
The view of a collimated telescope as seen through the 
focuser of the NexStar 114/130  reflector  models.