The display scrolls the compartments which are activated in menu 7 (Compartment settings). 
 
Remarks: 
If there is a communication problem with the serial port of the refrigeration unit or if the refrigeration unit is 
switched off, the message “Unit connection lost” is displayed. 
If the refrigeration unit is switched on but all compartments are switched off, the message “All compartments 
off” is displayed. 
 
 
4 Parameter 
menu 
 
The DataCold 500 T/R recorder has been designed to enable a multiple number of desired applications for 
individual customers. By using the corresponding parameter settings you can adjust the recorder functionality to 
the required needs. This chapter gives an overview and structure of the various parameters available. 
 
 
To enter the parameter menu press the green button for 2 seconds. The 
display will show: "ENTER PIN code". The factory setting of the PIN code is  
1111 but can be adjusted by the supervisor any time. (see menu 10.5) 
 
Parameter Settings 
ENTER PINCODE  
**** 
   1    2    3    4
  
 
 
After entering the correct PIN code you have access to the parameter menu’s and the first menu level is 
displayed. Select the desired menu with [<], [>] and press [edit] to enter one of the following parameter 
menu’s: 
 
5.  Temperature input settings 
6.  Digital inputs settings  
7. Compartment 
settings 
8. Alarm 
settings 
9. Printer 
settings 
5. Temperature inp. 
settings 
  
     ↓    edit    <-menu
 
10. General settings 
11. Communications settings 
 
 
 
 
 
 
Menu 5 :  
Temperature inputs settings 
 
4 inputs for temperature measurement, you can switch on/off each input and assign a name depending on the 
sensor position. Standard input 1 is pre-set as „Return air“ and input 2 as „Rear“. 
 
T1 Input 
>on/off 
 
If ‘on’, input 1 will be measured, displayed and stored into memory. Printing of input 1 is assigned in the 
compartment setting (menu 7). If ‘off’, go to menu 5.2. 
 
5.1.1.  Name >Return 
air 
You can select a sensor name from the table or enter a free text. (Free text 
is not translated when changing the language) 
5.1.1 Name 
 Free text 
<-cncl    accept 
       ↓        <        >
 
5.1.2.  Name >Free 
text 
 
Enter a text as desired via the four buttons. 
 
 
T2 Input 
>on/off. Menu structure as 5.1