FINNED WATER-TUBE POOL HEATERS 
PART 1 - GENERAL 
1.1 SUMMARY 
A.  Section includes gas-fired, copper finned-tube pool heaters. 
B. Related 
Sections 
Specifier Note:  Use as needed 
1.  Building Services Piping – Division 23 21 00 
2.  Breeching, Chimneys, and Stacks (Venting) – Division 23 51 00 
3.  Electrical – Division 23 09 33 
1.2 REFERENCES 
A.  ANSI Z21.10.3/CSA 4.3 
B.  ASME, Section IV 
C.  2006 UMC, Section 1107.6 
D.  ANSI/ASHRAE 15-1994, Section 8.13.6 
E.  National Fuel Gas Code 
F. NEC 
G.  ASME CSD-1, 2006 
1.3 SUBMITTALS 
A.  Product data sheet (including dimensions, rated capacities, shipping weights, accessories) 
B. Wiring 
diagram 
C. Warranty 
information 
D.  Installation and operating instructions 
1.4 QUALITY 
ASSURANCE 
A. Regulatory 
Requirements 
1.  ANSI Z21.10.3/CSA 4.3 
2.  Local and national air quality regulations for low NOx (0-30 PPM NOx emissions) pool heaters  
B. Certifications 
1. CSA 
2.  ASME HLW Stamp and National Board Listed 
3. ISO 
9001 
1.5 HEAT 
EXCHANGER 
WARRANTY 
A.  Limited ten-year warranty from date of installation  
B.  Limited twenty-year thermal shock warranty from date of installation 
PART 2 - PRODUCTS 
2.1 MANUFACTURER 
A. Raypak, 
Inc. 
1.  Contact: 2151 Eastman Ave., Oxnard, CA 93030; Telephone: (805) 278-5300;  
Fax: (800) 872-9725; Web site: www.raypak.com 
2.  Product: Hi Delta
®
 copper finned-tube pool heater(s) 
2.2 POOL 
HEATERS 
A. General 
 
Catalog No.:      6000.62 
Effective: 9-15-08
Replaces: 6-1-08
HI DELTA
®
, TYPE WHP - MODELS 2072B-2342B
SUGGESTED SPECIFICATIONS