Toshiba TOSVERT VF-AS1 Manuel D'Instructions

Page de 73
E6581315
63
„
 Command 
parameters
For those parameters that contain data only in the RAM and not in the EEPROM, their data return to
initial values when the power is turned off, in failure resetting, or when standard shipment settings
are set.    Note that parameters without data storage in the EEPROMs will be written in the RAM only
even if the command W (writing in EEPROMs and RAM) is executed.
Q 
Commands                           NOTE : Data is expressed in decimal notation.
Communica-
tion
Num-
ber.(HEX)
Function
Adjustment Range
Min.
Setting
Unit
Initial
Value
Write
During
Operation
EEP
ROM
FA00
Command 1 (2-wire RS485)
1
0 to 65535
0
yes
None
FA01
Frequency command value (2-
wire RS485)
1
0 to Max. frequency
()
0.01Hz
0
yes
None
FA03
Operation panel operation
frequency *
2
Low-limit frequency
() to High-limit
frequency ()
0.01Hz
0
yes
Available
FA04
Command 1 (4-wire RS485)
1
0 to 65535
0
yes
None
FA05
Frequency command value (4-
wire RS485)
1
0 to Max. frequency
()
0.01Hz
0
yes
None
FA10
Panel key selection
4
0: Main unit
1: Comunication
0
yes
None
FA11
External communication key
data
4
0 to 65535
0
yes
None
FA20
Command 2 (2-wire RS485) 
1
0 to 65535
0
yes
None
FA22
Command 2 (4-wire RS485) 
1
0 to 65535
0
yes
None
FA30
Torque command value (2-wire
RS485)
-250.00 to 250.00
0.01%
0
yes
None
FA32
Torque command value (4-wire
RS485)
-250.00 to 250.00
0.01%
0
yes
None
FA50
Terminal output data
3
0 to 255
1
0
yes
None
FA51
FM analog output data
3
0 to 2047
(11-bit resolution)
1
0
yes
None
FA52
AM analog output data
3
0 to 2047
(11-bit resolution)
1
0
yes
None
FA53
MON1 analog output data
3
0 to 2047
(11-bit resolution)
1
0
yes
None
FA54
MON2 analog output data
3
0 to 2047
(11-bit resolution)
1
0
yes
None
FA65
Select display by communica-
tion
4
0 to 2
1
yes
Available
FA66
Numerical display data
4
0-9999
1
0
yes
Available
FA67
Decimal point position
4
0 to 2
0
yes
Available
FA68
LED data for unit 0
4
0 to 3
0
yes
Available
FA70
ASCII display data 1
First digit from left
4
0 to 127
100
(‘d’)
yes
Available
FA71
ASCII display data 1
Second digit from left
4
0 to 255
65
(‘A’)
yes
Available
FA72
ASCII display data 1
Third digit from left
4
0 to 255
116
(‘t’)
yes
Available
FA73
ASCII display data 1
Fourth digit from left
4
0 to 127
65
(‘A’)
yes
Available
FA74
LED data for unit1
4
0 to 3
0
yes
Available
FA75
ASCII display data 2
First digit from left
4
0 to 127
48
(‘0’)
yes
Available
FA76
ASCII display data 2
Second digit from left
4
0 to 255
48
(‘0’)
yes
Available
FA77
ASCII display data 2
Third digit from left
4
0 to 255
48
(‘0’)
yes
Available
FA78
ASCII display data 2
Fourth digit from left
4
0 to 127
48
(‘0’)
yes
Available
FA79
LED data for unit 2
4
0 to 3
0
yes
Available
FA80
Block communication mode
4
0 to 1
0
yes
Available
efesotomasyon.com -Toshiba inverter,drive,servo,plc