Datalogic Scanning Multi-Battery Charger Fascicule

Page de 1
 
 
 
 
DATALOGIC SKORPIO™ 
MULTI-BATTERY CHARGER 
 
 
 
 
 
 
Figure 1 
 
The Datalogic Skorpio™ Multi-Battery Charger, with its 4 slots, 
allows you to charge the Datalogic Skorpio™ and Datalogic 
Skorpio-GUN™ battery packs. 
 
 
TECHNICAL FEATURES 
 
ELECTRICAL 
Power supply 
12-14 VDC 
Max consumption 
4 A 
Charge time 
3 h 30 min Skorpio™ 
5 h min Skorpio-GUN™ 
PHYSICAL 
Dimensions (LxWxH) 
20 x 13.7 x 4.3 cm 
(7.9 x 5.4 x 1.7 in) 
Weight (without batteries)  687 g (24.2 oz) 
LEDs 
4 Charger Status LEDs 
1 Power on LED 
ENVIRONMENTAL 
Working temperature 
0° to +40 °C (+32° to +104 °F) 
Storage temperature 
-20° to +70 °C (-4° to +158 °F) 
Humidity 
95% without condensation 
Degree of protection 
IP30 
 
 
CONNECTIONS 
 
Plug the power supply into the connector positioned on the 
Datalogic Skorpio™ Multi-Battery Charger base. Then plug the 
power supply into a socket. 
 
 
Figure 2 
 
 
ACCESSORIES 
 
94ACC4595 FPS18 power supply without power cord 
94ACC1150 Power cord EU 3- pin 
USING DATALOGIC SKORPIO™ MULTI-BATTERY CHARGER 
 
Charge Function 
 
Correctly insert the battery pack of the Datalogic Skorpio™ or 
of the Datalogic Skoprio-GUN™ into one of the free slots: 
simply press it into the slot until the battery latch is 
automatically closed; charging starts automatically. 
 
 
 
Figure 3 
 
To remove the battery pack release the latch on the charger 
for the Datalogic Skorpio™ and the latch on the gun battery 
pack for the Datalogic Skorpio-GUN™ as indicated in figure 4: 
 
 
 
Figure 4 
 
 
Battery Charging Status LED Description 
 
LED  
Status 
Power 
Green 
It is constant when the 
battery charger is powered 
Charger Green 
Empty 
slot 
 Red 
Charging 
 Green  Charge 
completed 
 Orange 
blinking 
Error 
 
 
 
COMPLIANCE 
 
FCC Compliance 
 
Modifications or changes to this equipment without the 
expressed written approval of Datalogic could void the 
authority to use the equipment. 
 
This device complies with PART 15 of the FCC Rules. 
Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference 
which may cause undesired operation. 
 
This equipment has been tested and found to comply with the 
limits for a Class A digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, 
if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential 
area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own 
expense. 
 
 
 
 
 
 
 
 
 
 
 
822000761 (Rev. B) 
Battery Charging State LEDs
Power on LED