ACCESSORY
 WARNING: Accessory other than these shown below
can lead to malfunction and resulting injuries.
STANDARD ACCESSORY
Dipstick ........................................... 1
APPLICATIONS
Air source of the pneumatic nailer and stapler.
 WARNING: Never use compressor for applications other
than compressor for pneumatic nailer and
stapler.
PRIOR TO OPERATION
1.
Power source
Ensure that the power source to be utilized conforms
to the power source requirements specified on the
product nameplate.
2.
Power switch
Ensure that the knob of the pressure switch is in the
“OFF” position (Fig. 2). If the plug is connected to a
receptacle while the knob is in the “ON” position, the
compressor will start operating immediately and can
cause serious injury.
5.
Dipstick insertion and oil level check
Use a screwdriver or similar tool to remove the plastic cap
on the lower part of the cylinder (Fig.3).
3.
Extension cord
When the work area is far away from the power source,
use an extension cord of sufficient thickness and rated
capacity (refer page 6). The extension cord should be kept
as short as practicable.
 WARNING: Damaged cord must be replaced or
repaired.
4.
Confirm the power receptacle
If the power receptacle only loosely accepts the plug, the
receptacle must be repaired. Contact the nearest electric
store for repair service.
If such a faulty receptacle is used, may cause overheating,
resulting in a serious hazard.
ON
Knob of the pressure switch
OFF
Insert the accessory dipstick all the way to the bottom.
Remove the dipstick and make sure the oil level is within
the range of the dipstick notches (Fig.4).
 WARNING: Drain tank to release air pressure before
removing the dipstick.
 WARNING: Make sure air vent in dipstick is free from
debris. If air vent is blocked pressure can
build in crankcase causing damage to
compressor and possible personal injury.
When the oil volume is insufficient, refer to the section “Oil
change-oil topping off” on page 10 for a description of how
to supply the oil.
6.
Right  running position
Position the compressor on a flat surface or one with an
inclination of 10° at the most, in a well ventilated area away
from atmospheric agents and not in explosive areas (Fig.5).
 CAUTION : In order to avoid damaging the compres-
sor, do not allow the unit to be tilted more
than 10° when  operating.
NOTE: When operating or storing the copmressor, set 4
rubber bumpers downward on the floor (Refer to
Fig.1)
7.
Temperature
Operating temperatures are between 32°F and 104°F
(0°C and 40°C).
 CAUTION: Never operate in temperatures below 32°F
(0°C) or above 104°F (40°C).
Air vent
Dipstick
Max
Min
10°max
10°max
Plastic cap
Cylinder