Set DIP Switches
1.
Set the DIP switches according to equipment 
installed in the home:
a. Use default position set at the factory when all 
devices (air cleaner, UV air treatment system, 
humidifier) are installed in the home.
b. Move DIP switch to left (off position) when a 
device is not installed in the home.
NOTE:
The UV air treatment system and the 
humidifier settings are for one year. The 
air cleaner settings are selectable accord-
ing to homeowner activities and needs.
2.
Determine the air cleaner filter run time you desire 
and set the DIP switches accordingly:
a. If air cleaner filter is used, select desired filter 
time of 3, 6, 9 or 12 months. Follow the settings 
on the back of the W8600A to set the DIP 
switches for the desired number of months.
b. If air cleaner filter is not used, move the filter 
time DIP switches 4 and 5 to the left (off).
c. Use factory default settings to change the 
media filter or wash the electronic filter every 
three months.
 Install Batteries
1.
Remove the back cover by pressing in on the tab 
on the bottom edge (top is hinged).
2.
Install two AAA alkaline batteries (provided), in the 
harness on the back of the unit.
3.
Observe that the W8600A performs a self-test, 
beeping and flashing the LCD display individually 
for each device (air cleaner, UV air treatment sys-
tem, humidifier) installed in the home.
4.
Press and hold the black reset button on the bot-
tom of the device for five seconds or until the dis-
play stops flashing to start the timers.
5.
Observe Battery LCD:
a. On solidly means unit is correctly powered.
b. Flashing indicates battery requires replacing.
SERVICE
The unit beeps every fifteen minutes to indicate an LCD 
is flashing. This means that service or a replacement part 
is required.
1.
Replace or service the part corresponding with the 
LCD flashing.
2.
Replace the batteries within 30 seconds of removal 
to maintain the correct indication time.
3.
Within 30 seconds after replacing the batteries, if 
the LCD is blank, remove and install new batteries.
4.
Press and hold the black button on the bottom of 
the device to reset the timer after servicing or 
replacing parts.
TROUBLESHOOTING
LCD
If arrow is 
flashing or unit 
is beeping...
Reset by...
Battery
Batteries need 
changing.
Changing batteries 
within 30 seconds of 
removing old batteries 
to maintain correct 
indication time.
Air Cleaner
Media filter needs 
replacing or 
electronic filter 
needs washing.
Pressing and holding 
reset button for 10 
seconds or until arrow 
is no longer displayed.
UV Air 
Treatment
UV lamps need 
replacing in UV air 
treatment system.
Pressing and holding 
reset button for 10 
seconds or until arrow 
is no longer displayed.
Humidifier
Humidifier pad 
needs replacing.
Pressing and holding 
reset button for 10 
seconds or until arrow 
is no longer displayed.