Emerson 20/20 Manuel D’Utilisation

Page de 120
7 – 4
Vission 20/20 • Operation and Service Manual •Vilter/Emerson • 35391SC 1.8.5153
False Start 
•  This message appears when the compressor stops 
and the motor auxiliary contact fails to open. The 
message will also appear if the compressor shuts 
down and the amperage is 20% of the maximum amp 
setting, indicating that the starter is still energized.
Low Oil Level Trip 
•  This message appears when power is removed from 
the designated input module, refer to wiring dia-
gram. This safety will activate only after the oil level 
has been low for the time period defi ned by the “Low 
Oil Separator Safety Trip Delay” timer.
Section 7 • Alarms and Trips