Emerson 20/20 Manuel D’Utilisation

Page de 120
14 – 7
Vission 20/20 • Operation and Service Manual •Vilter/Emerson • 35391SC 1.8.5153
Slide Valve Actuator Troubleshooting Guide Blink Code
Vilter actuators communicate problems discovered by the internal diagnostics to the technician by LED blink codes. 
Only one blink code is displayed, even though it is possible that more than one problem has been detected. The actua-
tor motor will not operate until the error code is cleared by pressing the blue bottom, see Table 14-3. LED Blink Codes 
and Troubleshooting Guide.
Table 14-3. LED Blink Codes and Troubleshooting Guide (1 of 2)
Flash Pattern
* = ON                - = OFF 
Meaning
*-*-*-*-*-*-*-*-*-*-*-*-
Calibration step 1.
*---*---*---*---*---*---
Calibration step 2.
*--*--------------------
This indicates a zero span. This error can only occur dur-
ing calibration. The typical cause is forgetting to move 
the actuator when setting the upper limit of the span. 
If this is the case, press the blue button to restart the 
calibration procedure. This error can also occur if either 
or both of the slotted optocouplers are not working. If 
this is the case, the slide valve actuator will have to be 
replaced.
The operation of the slotted optocouplers can be tested 
as follows: 
1. Manually rotate the motor shaft until the aluminum 
photochopper fence is not blocking either of the opto-
coupler slots.
2. Using a digital multimeter, measure the DC voltage 
between terminal 3 of the small terminal block and TP1 
on the circuit board (see Note 1). The measurement 
should be between 0.1 and 0.2 Volts.
3. Next, measure the DC voltage between terminal 3 
and TP2 on the circuit board. You should measure be-
tween 0.1 and 0.2 Volts.
*-----------------------
A motor over-speed occurred. At some time during 
operation, the motor armature spun too fast for the 
encoder to measure. A nonfunctional motor brake is 
usually to blame. This error means that the slide valve 
actuator is no longer transmitting accurate position 
information. The actuator should be recalibrated as 
soon as possible, after the cause of the over-speed is 
identifi ed and corrected. This error will not clear until 
the actuator is re-calibrated.
Note 1:  TP1 and TP2 are plated-thru holes located close to the slotted optocouplers on the board. They are clearly 
marked on the board silkscreen legend.
Section 14 • Slide Calibration