Sterling 882.00274.00 Manuel D’Utilisation

Page de 51
Additive Feeders 
Chapter 4: Operation 
22 of 50 
Chapter 4:  Operation 
4-1 Start-up 
1.  Turn the power switch ON
2.  Set the desired feed rate on the RPM display using the up or down arrows. 
3.  Flip the motor switch to AUTO
If the additive feeder is installed correcly, it should begin operation at the desired RPM when 
the processing machine screw is in operation. 
4-2  Controller Description and Operation 
Identifying Control Panel Indicator Lights and Switches on the Controller 
Switches 
Power Switch. This switch turns the control ON and OFF
Motor Switch.  This switch has three (3) positions: 
•  OFF stops the auger motor. 
•  AUTO starts normal automatic operation. 
•  MANUAL operates the auger at the set point as long as the switch is held in this 
position.  Use this feature when calibrating the feeder or during cleanout. 
Indicator Lights 
Motor Light.  This indicator lights when the auger motor is turning. 
Auger Speed.  This LED displays the auger speed setpoint.