Ryobi R160 Manuel D’Utilisation

Page de 17
Page 13
ROUTER MODEL R165 (ONLY)
LIGHT BULB REPLACEMENT (MODEL NO.
R165 ONLY)
See Figure 16.
1.
UNPLUG YOUR ROUTER.
2.
Remove cutter from router. Refer to page 7 to remove
cutter.
3.
Adjust router to maximum height.
4.
Remove screws (A) and subbase (B). 
See Figure 16.
5.
Remove screw (C) and work light lens (D).
6.
With bulb (E) pointing toward you, pull bulb from socket.
7.
Install new bulb by reversing the above procedure.
8.
Reassemble all parts and tighten screws securely.
MAINTENANCE
PROPER CARE OF COLLET
From time to time, it also becomes necessary to clean your
collet and collet nut. To do so, simply remove collet nut from
collet and clean the dust and chips that have collected. Then
return collet nut to its original position. DO NOT tighten collet
nut on collet without a cutter installed.
LUBRICATION
All of the bearings in this tool are lubricated with a sufficient
amount of high grade lubricant for the life of the unit under
normal operating conditions.  Therefore, no further lubrication
is required.
PROPER CARE OF CUTTERS
Get faster more accurate cutting results by keeping cutters
clean and sharp. Remove all accumulated pitch and gum
from cutters after each use.
When sharpening cutters, sharpen only the inside of the
cutting edge. Never grind the outside diameter. Be sure
when sharpening the end of a cutter to grind the clearance
angle the same as originally ground.
Fig. 16
D
A
B
C
E
WARNING:
Failure to unplug your router could result in accidental
starting causing serious injury.