Mitsubishi Electronics 60/60S Manuel D’Utilisation

Page de 559
3.  Tool Offset (M system) 
3.1  Tool Offset 
 
 
 
I-118 
Refer to "3 (I). Tool Offset (L system)" for L system.
 
 
2)  Tool length measurement II 
 
 
Position the tool to the machine coordinate 
zero point. 
START 
Select measurement tool. 
To use gage block, etc., set the value of 
the basic height. 
Turn ON the machine operation board 
"TLM" switch. 
Move the tool to the measurement point by 
making jog feed or manual handle feed. 
Upon completion of measurement, specify 
the tool offset number. 
Check axis specification parameter "#2015 
tlml–" data of machine parameter. 
(Set the value of the distance from the 
reference point to table surface.) 
 
 
Set # ( 0 ) DATA (     
. ) and press the 
 
INPUT
  key. 
The data is displayed in SURFACE 
# 0 =                      . 
 
 
 
 
 
 
 
 
 
The message "TLM" is displayed on the 
TOOL OFFSET screen. 
Dummy tool length data "parameter tlml" - 
"#0" is displayed in the DATA (      ) field. 
 
 
 
 
The measurement value is displayed in the 
DATA (   ) field in sequence. 
The current value of the measurement axis 
is displayed under [MACHINE] Z. 
 
 
 
Set the offset number in # (      ) and press 
the 
 
 
INPUT
 key. 
The measurement data is displayed at the 
position of the specified offset number. 
 
Setting and display on the TOOL 
OFFSET screen 
On measurement, first check the TLM 
basic length. 
.........
.........
.........
.........
.........