Mitsubishi Electronics 60/60S Manuel D’Utilisation

Page de 559
4.  Parameters (User) 
4.5  BACKUP Screen 
 
 
 
I-170 
4.5.1  Backup Operations 
 
 
The parameters are backed up in the maintenance memory cassette with the following steps. 
 
 
"EMG EMERGENCY" will appear at the 
operation message area. 
   WORK PROCESS
I/O PAR
SETUP 
MENU 
 
 #( ) ( 
EMG EMERGENCY 
Execute emergency stop.
 
(1) 
  
 
 
 
  #(1) ( 
PLC STOP Y/N 
EMG EMERGENCY 
Input "1" at the setting area # (  ),
and press the 
 
 
INPUT 
 key. 
(2) 
"PLC STOP Y/N" will appear at the 
message area. 
   WORK PROCESS
I/O PAR
SETUP 
MENU 
  
 
 
 
  #(1) ( 
Y) 
BACKUP EXEC    Y/N 
EMG EMERGENCY 
Input "Y" at the setting area (    ),
and press the 
 
 
INPUT 
 key. 
(3) 
"BACKUP EXEC Y/N" will appear at the 
message area.
 
   WORK PROCESS
I/O PAR
SETUP 
MENU 
 
 
 
Input "Y" at the setting area (    ),
and press the 
 
 
INPUT 
 key. 
(4) 
 
 #(1) ( 
Y) 
BACKUP EXECUTION  
EMG EMERGENCY 
(a)  The message "BACKUP EXECUTION" 
will appear while the parameters are 
being backed up.
 
   WORK PROCESS
I/O PAR
SETUP 
MENU 
 
 
(b)  The message "BACKUP COMPLETE" will 
appear when backup is completed. 
 
 
 
 
 
  #( ) ( 
BACKUP COMPLETE   
EMG EMERGENCY 
   WORK PROCESS
I/O PAR
SETUP 
MENU 
 
 
 
(Note 1)  Other screens cannot be opened during this operation. 
(Note 2)  If the PLC is already stopped, step (3) is skipped. 
 
The PLC will not start running even when the operations are completed. 
(Note 3)  If the 
 
 
INPUT 
 key is pressed without inputting anything at the "~Y/N" display, the error "E01 
SETTING ERROR" will occur. 
(Note 4)  Even if the PLC RUN/STOP changeover is prohibited (R2925/bit2 ON), the PLC will stop with 
step (3).