Mitsubishi Electronics 60/60S Manuel D’Utilisation

Page de 559
5.  Program 
5.2  Menu Function 
 
 
 
I-179 
 
 
Extension operation menu is also highlighted when it is selected. When one extension operation menu 
is selected, its corresponding extension operation is enabled and programs cannot be edited. When no 
extension operation is selected, program can be edited. 
 
 
When an extension operation menu key is once pressed, the extension operation menu is selected. 
When the key is again pressed, the extension operation menu is unselected. At normal completion of 
setting processing, automatically it becomes unselected. 
 
 
(3)  Edit program call 
 
 
To edit a program on the EDIT screen, first press the extension operation menu key 
 
 
SEARCH
 or 
 
 
MAKE 
To edit an already stored program in memory, press 
 
 
SEARCH
. To store a new program in memory, press 
 
 
MAKE 
. For details, see 5.5. 
 
 
Once the program edit operation begins, the operation is as follows: If another function screen is 
operated during program edit operation and then the EDIT screen is reselected, the previously edited 
data will be displayed. In the following cases, the system enters the status in which nothing has been 
called. Thus, retry data search before edit operation. 
 
 
•  The program being edited on the EDIT screen is condensed by the condense function. The EDIT 
screen is then selected. 
 
 
•  The program being edited on the EDIT screen is merged with another program by the merge 
function. The EDIT screen is then selected. 
 
 
(4)  Large-size mode/small-size mode 
 
 
The EDIT and MDI screens can be switched between the large-size and small-size modes. 
 
 
O123 EDIT 
 
Machining program edit area 
(39 characters x 12 lines) 
 
SEARCH     MAKE     SMALL 
O123 EDIT 
 
Machining 
program edit 
area 
(39 characters x 
12 lines) 
 
Machining 
program address 
menu display 
area 
 
SEARCH     MAKE     LARGE   FILE 
40 characters
18 l
ines
 
80 characters
Large-size mode 
Small-size mode 
18 l
ines
 
 
 
 
 
In large-size mode, data search and program creation are enabled. 
 
 
The FILE menu is not available; refer to the data input/output program list to check the stored 
programs. 
  
(Note 
1)  Switching the mode in the EDIT screen automatically changes the mode in the MDI screen. 
  
(Note 
2)  During editing (while message "EDITING" is displayed on the lower right of the screen), 
menu keys 
 
 
LARGE 
 and 
 
 
SMALL 
 are disabled, i.e., pressing it does not change the mode. To 
change the mode, the 
 
 
INPUT
 key must be pressed to end editing. 
  
(Note 
3)  The mode thus set is held after the screen is changed or after power is turned OFF. 
  
(Note 
4)  If the system is changed while editing the machining program, the edited details will be 
canceled.