Mitsubishi Electronics 60/60S Manuel D’Utilisation

Page de 559
6.  Data In/Out 
6.2  DATA OUTPUT 
 
 
 
I-245 
6.2.4  Outputting Common Variable Data 
 
 
Common variable data can be output. The output operation can be performed even during automatic 
operation. 
 
 
(1)  Common variable data output operation 
 
1)  Data output starts and the contents of the 
output data and message "DATA OUT 
EXECUTION" are displayed.
 
2)  When tape end code % (EOR) is output, the 
data output completes with message "DATA 
OUT COMPLETE" displayed. 
 
 
 
  # (    5 ) DATA (                  ) 
 <OUTPUT DATA> 
        % 
 
 
DATA OUT COMPLETE 
  # (        ) DATA (                  ) 
Press the 
 
 
INPUT 
 key. 
Set the data type to the common 
variable. 
#  ( 5 )  DATA  (    ) 
 <OUTPUT DATA> 
 
 
 
DATA OUT EXECUTION 
  # (    5 ) DATA (                  ) 
 
 
(Note) 
For the multiple system, data will be output following the parameters below. 
#1303 V1comN (#100 to set number) system common variables 
#1304 V0comN (#500 to set number) system common variables 
The number of data items designated in the parameter will be output in the same manner as the 
single system. The other common variables will be output for each system.