7.  Diagnosis 
7.4  PLC Interface Diagnosis 
 
 
 
I-288 
7.4.4  PLC Interface Signal Forcible Definition (Modal Type) 
 
 
This is PLC interface signal forcible definition of modal type. Once it is set, it is held until canceled. 
 
The device signals that can be set by using this function are X, Y, U, W, S, M, G, F, L, E, T, Q, C, B, D and 
R. 
 (1) 
Mode 
setting 
 
 
Set the device number to be forcibly defined in DEVICE (   ), definition data in DATA (   ), and 2 in 
MODE (   ), then press the 
 
 
INPUT 
 key. The data is processed and forcibly defined. 
 
 [PLC-I/F] 
ALARM/DIAGN 4 
 <SET 
DATA> 
X0008=0001 
 
 
 76543210 
HEX   
76543210 
HEX 
  X0008 ooooo1o1 
05 
D0005  oooooooo 
 
  X0010 oooooooo 
00 
  o11oo1oo 
 
  X0018 o1o1oooo 
50 
D0006  1oooooo1 
 
  X0020 1o1ooo11 
A3 
  ooooo1oo 
 
 
 [PLC-I/F] 
ALARM/DIAGN 4 
 <SET 
DATA> 
 
 
 
 76543210 
HEX   
76543210 
HEX 
  X0000 oooooooo 
00 
D0005  oooooooo 
00 
  X0008 ooooo1o1 
04 
  o11oo1oo 
64 
  X0010 oooooooo 
00 
D0006  1oooooo1 
81 
  X0018 o1o1oooo 
50 
  ooooo1oo 
04 
     
     
     
     
  DEVICE  DATA 
MODE  DEVICE  DATA  MODE 
    ( X8      )    (      1 )      ( 2) 
(            )    (          )      (    ) 
Press the 
 
 
INPUT 
 key. 
Set X8 in DEVICE (      ), 
1 in DATA (      ), and 
1 in MODE (      ). 
ALARM SERVO SPINDLE
PLC-I/F 
MENU 
X0008 is displayed at the beginning and bit 0 changes to "1".
(Example 3) 
A maximum of four sets of forcibly 
defined device numbers and 
numeric data are displayed. 
 
 
 
A maximum of four sets can be forcibly defined in mode 2. If four sets have been defined and additional 
setting is made, forward feed is made and the subsequent four sets become effective.