7.  Diagnosis 
7.5  Absolute Position Monitor 
 
 
 
I-292 
 
# 
Parameter 
Explanation 
Setting range (unit)
  0  INIT. SET 
Select the axis for which absolute position initialization is to 
be performed: 
  0: Do not perform initialization. 
  1: Perform initialization. 
  
(Note)  "0" is set when the power is turned ON again. 
0/1 
  1  ORIGIN 
This parameter is valid when the marked point alignment 
method is used. Specify "1" when the machine has been 
positioned to the basic point. 
  
(Note)  This parameter is invalid for other methods. 
0/1 
  2  ZERO 
This parameter is used to determine the basic machine 
coordinate system. 
Specify the coordinates of the machine basic position seen 
from the zero point of basic machine coordinate system or 
absolute position basic point. 
(Whether the machine basic position or absolute position 
basic point is used is determined by data specified for "#2059 
zerbas" of the setup parameter.) 
 
 
Zero point of basic 
machine coordinate 
system 
Values set to #2[ZERO]
Machine basic 
position 
 
±99999.999 (mm) 
 
 
 
This section explains only the ABS POSITION SET screen. 
For details of the actual absolute position initialization and display contents, see Chapter III Section 4 