Mitsubishi Electronics 60/60S Manuel D’Utilisation

Page de 559
11.    Visual Analyzer (Waveform display) 
 
 
 
I-371 
11.  Visual Analyzer (Waveform display) 
 
Pressing the function selection key 
 
 
F0 
  displays the VISUAL ANALYZER screen. On this screen, changes 
in the spindle and servo operation status can be displayed in time units simultaneously for both channels. 
During synchronous tap, the difference of the spindle and tap axis position deviation (synchronous error 
amount) can be displayed as a waveform. 
The waveform data can be output. Refer to section "6.2.6 Outputting Waveform Data" for details. 
 
(Note)  The VISUAL ANALYZER screen is valid when the setup parameter "#1222 aux06/bit2" is set to 1. 
 
 
SINGLE AUTO DISPLAY 
 
 
[VISUAL ANALYZER] 
VISUAL ANALYZER 1. 
 
#1 time 
(1000) 
(ms/div)  
  2 CH1 ax 
(X1) 
 3 data 
(1) 
 4 range  (  100) 
 5 level 
(0) 
  6 CH2 ax 
(    ) 
 7 data 
( ) 
 8 range  (     ) 
 9 level 
( ) 
10 type 
( ) 
11 signal 
(    )  -5 
 
#(  )data(     )( ) 
 
 
 
# Parameter 
Description 
Setting range 
(units) 
time (ms/div) 
Specify the unit of a time axis (horizontal axis) 
gradation in milli-second (ms). 
1 to 9999 
CH1 ax 
Specify the name of the axis to be displayed for CH1. 
No waveform data is displayed if (    ) is left blank. 
Input "/" to erase the displayed waveform. 
Servo axis: 
Axis name 
[2 characters] 
(X1, Y1, Z1, etc.) 
Spindle: 
S1 to S4 
(Just S is sufficient 
for the first 
spindle.) 
"/" will cancel the 
axis name.