Mitsubishi Electronics 60/60S Manuel D’Utilisation

Page de 559
6.  Operation Panel Switch Functions 
6.14  Handle Interruption 
 
 
 
II-25 
Absolute value update conditions for automatic handle interruption 
 
 
Absolute data update 
MONITOR 2 screen 
manual interruption 
distance display 
 ON
 "1"
Absolute value is 
updated. 
Not updated. 
Parameter #1145 
 
 I_abs 
ON 
"1" 
Parameter #1061 
intabs (Every axis) 
 OFF
 "0"
Absolute value is not 
updated. 
Updated. 
 
 ON
Absolute value is 
updated. 
Not updated. 
 
OFF 
"0" 
PLC interface 
manual absolute 
switching 
 OFF
Absolute value is not 
updated. 
Updated. 
 
 
Program path 
(G90 X_ Y_;) 
Distance of interruption by manual handle
Path after interruption
Path after interruption 
(Absolute value mode, program absolute value update invalid)
 
 
 
 
 
 
 
Program path 
(G90 X_ Y_;) 
Distance of interruption by manual handle
Path after interruption
Path after interruption 
(Absolute value mode, program absolute value update valid, single block operation)