Mitsubishi Electronics 60/60S Manuel D’Utilisation

Page de 559
7.  Troubleshooting 
7.2  When in Trouble 
 
 
 
III-54
 
(1)  Problems related to the power supply 
 
The power does not turn ON. 
 Cause 
Remedy 
 
The power cord is disconnected or 
loose. 
Check the cable between the NC unit and the external 
power supply, and between the external power supply and 
socket. Make sure that the cable is inserted securely. 
Check that there are no wires broken in the cable. If broken, 
replace the cable. 
 
The door interlock is applied. 
If the control panel door is not completely closed, close it. 
If the door interlock is applied even when the door is closed, 
the door interlock circuit is damaged. Repair it. 
 
There is a problem in the power 
socket. 
If the socket has a switch, turn the switch ON.   
Make sure that the specified power voltage and power 
frequency is being output from the socket. 
 
The external power supply is 
faulty. 
Check that the power can be turned ON with just the 
external power supply.  
(Note)  Depending on the external power supply being 
used, the power may not turn ON in the no-load 
state, so install a slight load and check. 
 
The ON/OFF cable is short- 
circuited. 
Disconnect the ON/OFF cable and check that it is not 
short-circuited. If short-circuited, replace the cable. 
 
The external power supply's input 
voltage is not as specified. 
Check that the input voltage is within 200 to 230VAC +10 to 
–15%, 100 to 115VAC +10 to –15%, and 24VDC±5%. 
The external power turns ON but the NC control power does not turn ON. 
 Cause
 
Remedy 
 
The external power supply output 
is not correct.  
Disconnect the cable between the NC unit and the external 
power supply, and check that the external power supply 
output is normal.   
Wire the cable between the NC unit and external power 
supply, and check that the external power supply output is 
normal. 
 
The cable connected from the NC 
unit to the peripheral device is 
short-circuited. 
Disconnect the cable connected to the peripheral device 
one at a time and check that the power turns ON. Check that 
there are no short-circuited cables. 
 
There is a short circuit in the 
configuration card. 
Remove the removable cards one at a time and check that 
the power turns ON.  
Check that there are no short-circuited cards.  
 
 
         
 
 
 
 
 
 
 
 
 
Do not apply voltages other than those indicated in this manual on the connector.  
Doing so may lead to destruction or damage. 
Incorrect connections may damage the devices, so connect the cables to the 
specified connectors. 
Do not connect or disconnect the connection cables between each unit while the 
power is ON. 
Do not connect or disconnect the PCBs while the power is ON.
 
CAUTION