8.  Maintenance Functions 
8.2  Data Sampling 
 
 
 
III-73
 
8.2.3  Setting and Display Items 
 
The various data related to sampling of data is set and displayed on the NC-DATA SAMPLING screen. 
 
 
AUX-PRM AUX-MON 
SUPPORT 
 MENU 
 [NC-DATA SAMPLING] 
ALARM/DIAGN 11.2/2 
 
 # 0 SMT START 
SMT COUNTER 
 <STATE> Sampling stop 
 
<BASIC>  
<EXTENT> 
 # 1 CYCLE 
#11 ADR1 
00000300 
#21 PROCESS FORM 
 # 2 MARKS 
#12 ADR2 
00010000 
#22 E-CONDITION 
 # 3 BUFFER 
#13 ADR3 
00000000 
#23 VARIABLE NO. 
 # 4 CAPACITY 
#14 ADR4 
00000000 
#24 PLC DEVICE 
∗X0000 
 # 5 S-CONDITION 
#15 ADR5 
00000000 
#25 ADDRESS 
00000000 
 
 
 #16 
ADR6 
00000000 #26 
DATA 00000000 
  
 
#17 ADR7 
00000000 
#27 DATA MASK  00000000 
  
 
#18 ADR8 
00000000 
 
#(    )  (                                ) 
 
 
(Note 1)  #21 to #27 are extension functions and normally do not need to be set. 
(Note 2)  The data cannot be set when "#1224 aux08/bit0" is set to "0". 
 
(1) STATE 
display 
The current status is displayed. 
 
Display
 
Status
 
"sampling"
 
Sampling is being executed.
 
"sampling stop"
 
Sampling is not being executed, or the sampling process has 
completed.
 
"TRIGGER WAIT"
 
When #5 is not set to "0" (manual start), this indicates that state 
from when #0 was set to "1" to when the sampling start trigger 
was detected and sampling was started.
 
 
(2)  SMT COUNTER (sampling counter) 
The position of the sampling buffer during the sampling process is displayed. 
When the sampling buffer is valid, the head of the buffer can be seen with the value of the counter at the 
end of sampling. 
 
 
 
 
   Sampling buffer 
 0 
 
 1 
 
 : 
 
 
n-1 
End of buffer (newest data) 
   Sampling counter (n) 
→ 
Head of buffer (oldest data) 
 :