Mitsubishi Electronics 60/60S Manuel D’Utilisation

Page de 559
2.  Monitor 
2.3  COMMAND 
 
 
 
I-47
 
2.3.3  Total Integrating Time Display 
 
 
By switching the screen from the execution program's monitor screen by using the 
 
 
NEXT 
PAGE 
 
key, the TIME 
screen is displayed. 
 
POSI COORDI
COMMAND 
SEARCH MENU 
 [TIME] 
MONITOR  3.3/3
 O12345678 
 
N12345-12 
 <SUB> 
1000  N  200-30 
 
 # 1  DATE 
99/12/14 
   2  TIME 
13:27:59 
   3  POWER 
9999:59:59 
   4  AUTO OP 
0: 0: 0 
   5  AUTO STL 
0: 0: 0 
   6  EXT TIME1 
0: 0: 0 
   7  EXT TIME2 
0: 0: 0 
   
   
   
 #( ) DATA(        ) (    ) (    ) 
 
 
Display item 
Explanation 
O12345678  N1234-12 
The currently executing program number, sequence number, and 
block number are displayed. 
<SUB>  O1000   N200-30 
When a subprogram is being executed, the program number, 
sequence number, and block number of the subprogram are 
displayed. 
#1 DATE 
99/12/14 
 2  TIME 
13:27:59 
 3  POWER ON  9999:59:59 
 4  AUTO OP 
0: 0: 0 
 5  AUTO STL 
0: 0: 0 
 6  EXT TIME 1 
0: 0: 0 
 7  EXT TIME 2 
0: 0: 0 
The date and time are set and displayed. 
year/month/day 
 
hour : min : sec 
The total integrating time in each operation state is displayed. 
 
 
 (1) 
TIME 
setting 
 
 
Set the number, hour, minute, and second corresponding to the TIME to be set. 
 
Set 3 in # (      ). 
Set 0 in DATA (   ) (   ) (   ) 
Press the 
 
 
 
 
INPUT 
 
 key. 
  #3 POWER ON  0: 0: 0  
POSI COORDI
COMMAND
SEARCH MENU 
 # (3) 
DATA  (  0  )  (  0  ) 
(  0  ) 
 
 
 
DATE
  : Set date (set "YEAR" in last 2 digits of Gregorian calendar) 
 
 
TIME
  : Set time in 24-hour mode. 
 
 
POWER ON  : Total integrating time of the time from control unit power ON to OFF. 
 
 
AUTO OP
  : Total integrating time of the work time from AUTO STL button pressing in the memory 
(tape) mode to M02/M30 or reset button pressing. 
 
 
AUTO STL   : Total integrating time during automatic starting from AUTO STL button pressing in the 
memory (tape) mode or MDI to feed hold stop, block stop, or reset button pressing. 
 
 
EXT TIME 1  : Dependent on PLC sequence. 
 
 
EXT TIME 2  : Dependent on PLC sequence. 
  
(Note)  Integration time (#3 POWER ON to #7 EXT TIME 2): When display reaches the maximum 
value (9999:59:59), integration is stopped and the maximum value remains displayed.