Mitsubishi Electronics E70 Manuel D’Utilisation

Page de 214
E70 Series Connection Manual
4.2 Connection of Control Unit
85
4.2.6 Connecting with RS-232C Device
(1)
Connect the RS-232C device to the connector SIO. 
<Related items>
Cable drawing: "Cable: F034/F035 Cable"
Connector pin assignment: "General Specifications: Control Unit" (SIO connector)
SIO
 
1ch
2ch
F035 cable
F034 cable
Cable name
RS-232C device
F035 cable
Control unit
General-purpose cable 
See (2)
[SIO]
: 10120-3000VE
: 10320-52F0-008
[1ch] [2ch]
: CDB-25S
: CD-SC-111
: UL1061-2464 AWG22×12P
SIO
1ch
FG
12
2
13
3
14
4
16
6
1
17
7
18
8
19
9
20
10
11
SD1(TXD1)
RD1(RXD1)
RS1(RTS1)
CS1(CTS1)
ER1(DTR1)
DR1(DSR1)
0V
SD2(TXD2)
RD2(RXD2)
RS2(RTS2)
CS2(CTS2)
ER2(DTR2)
DR2(DSR2)
0V
2
3
4
5
20
6
8
9
7
2
3
4
5
20
6
8
9
7
2ch
Reserved
Reserved
Reserved
Reserved
: HD-LNA
Connector
Case
Manufacturer : 3M
Connector
Contact
Lock nut
Manufacturer
Wire material
Recommended
 manufacturer
: Oki Electric Cable
: Hirose Electric