Metrologic Instruments MLPN 2168 Manuel D’Utilisation

Page de 19
Appendix A (Continued) 
Operational 
Depth of Scan Field 
203mm to 457mm (8" to 18") 
Scan Speed 
Model 870 1250 scan lines per second 
Model 875: 450 scan lines per second 
Scan Pattern 
Model 870: Omnidirectional (20 interlocking lines) 
Model 875: 6-line raster 
Indicators 
LED: green=on ready to scan; red=good read 
Beeper Operation 
Selection of 3 tones for “Good Read” 
Maintenance Required 
Clean window periodically 
Decode Capability 
Autodiscriminates 
System Interfaces 
RS-232C; Light Pen Emulation; OCIA 
Optional Interfaces 
Opto coupled 6 amp US and Canada, 5 amps EEA countries 
TRIAC output; object sensor input 
Print Contrast 
35% minimum reflectance difference 
Roll, Pitch, Yaw 
360°, 60°, 60° 
Environmental 
Storage Temperature 
-40°C to 60°C (-40°F to 140°F) 
Operating Temperature 
0°C to 35°C (32°F to 95°F) 
Humidity 
5% to 95% relative humidity, non-condensing 
Light Levels 
Up to 3200 foot candles - works in direct sun 
Ventilation 
None required 
Shock 
100g for 1ms 
ESD 
8kV IEC 801-2 
Contaminants 
Protects against dust, falling dirt, and dripping
non-corrosive liquid 
Specifications subject to change without notice