Metrologic Instruments IS1000 Manuel D’Utilisation

Page de 92
 
 
 
 
 
 
 
IS1000  –  Configuration Guide 
27
START OF CONFIGURATION 
END OF CONFIGURATION 
3.2.7. Start/Stop 
This function activates the transmission of the start and stop characters (sign ¸). 
 
 
 
 
3.2.8. Modulo 43 Algorithm 
Code 39 is strongly self checked and most situations do not require a check 
character. If a specific application requires exceptional data security, a check 
character can be added as the last character of the code. 
Example: 
Message: 12345/ABCDE 
Sum of values: 1 + 2 + 3 + 4 + 5 + 40 + 10 + 11 + 12 + 13 + 14 = 115 
Divide 115 by 43. The quotient is 2 with the remainder 29. The check character is 
the character corresponding to the value of the remainder, which is 29 in this 
example, corresponding to the character T. 
The complete message, including check character is: 12345/ABCDET. 
Numerical value assignments for computing the optional check character: 
Character 
Value 
Character 
Value 
Character 
Value 
0 0  F 15 U 30 
1 1 G 16 V 31 
2 2 H 17 W 32 
3 3  I 18 X 33 
4 4  J 19 Y 34 
5 5 K 20 Z 35 
6 6  L 21 - 36 
7 7 M 22 . 37 
8 8 N 23 
Space 
38 
9 9 O 24 $ 39 
A 10  P 25  /  40 
B 11 Q 26  + 41 
C 12  R 27 % 42 
D 13  S 28   
 
E 14  T 29   
 
 
 NOT TRANSMITTED * 
TRANSMITTED