IS1000  –  Configuration Guide 
30
START OF CONFIGURATION 
END OF CONFIGURATION 
3.3.3. Variable Lengths Authorized 
 
 
 
 
 
 
 
 
How to calculate the check digit value: 
Example: 
Message: 14356 
Add the odd positions: 1 + 3 + 6 = 10 
Multiply by 3 = 30 
Add the even positions. 30 + 4 + 5 = 39 
The check digit is the complement to the next ten: CK = 40 – 39 = 1 
The printed message will be: 143561 
 
 
 
 
 
 
 
 
 
 
The mode Check Digit Not Verified is not advised, missing characters can occur in 
case of incomplete scanning of a code. 
ACTIVATED 
CIP CHECK DIGIT 
VERIFIED BUT NOT TRANSMITTED 
CIP CHECK DIGIT 
VERIFIED AND TRANSMITTED 
 CHECK DIGIT NOT VERIFIED * 
CHECK DIGIT 
VERIFIED BUT NOT TRANSMITTED 
CHECK DIGIT 
VERIFIED AND TRANSMITTED 
!   
Caution: