TROUBLESHOOTING AND MAINTENANCE
5
4
Close the front cover and side cover.
Make sure that the 
misfeed message is 
cleared.
B: Misfeed in the fusing area
1
Open the bypass tray and the side 
cover.
2
Press and pull it open gently on both 
sides of the front cover.
3
Turn the roller rotating knob in the 
direction of the arrow.
4
Lift the fusing unit release levers and 
carefully remove the misfed paper.
5
If you were unable to remove the 
misfeed in step 4, press down on the 
fusing unit paper guide knob to open 
the paper guide, and carefully remove 
the misfed paper. 
6
Close the fusing unit paper guide and 
press down on the fusing unit release 
levers.
7
Close the front cover and side cover.
Make sure that the 
misfeed message is 
cleared.
The fusing unit is hot. Do not touch 
the fusing unit when removing 
misfed paper. Doing so may cause a 
burn or injury.
Roller rotating knob
Fusing unit release levers
Warning
• Do not touch the photoconductive drum 
(green portion) when removing the misfed 
paper. Doing so may damage the drum 
and cause smudges on copies.
• Take care not to let unfixed toner on the 
misfed paper soil your hands or clothes.
Caution