3-1 Required Equipment
The following equipment is necessary for adjusting the monitor:
Computer with Windows 95, Windows 98, or Windows NT.
MTI-2055 DDC MANAGER JIG
3-2 DDC EDID Data Input
1. Input DDC EDID data when replacing AD PCB.
2. Receive/Download the proper DDC file for the model from HQ quality control department.
Install the below jig (Figure 1) and enter the data.
3 Alignments and Adjustments
This section of the service manual explains how to use the RS232 JIG.
This function is needed for AD board change and program memory (IC200) change.
This function is needed for AD board change and program memory (IC200) change.
MTI-2055
DDC Manager
DDC Manager
Parallel Connector
(25P Cable)
Connect Monitor
(Signal Cable)
Figure 1.
3-3 Hidden Key list