A  value  of  F1h  written  by the  host  into  the  device’s  Sector  Count  Register  before  issuing  this  command  shall 
cause  this  feature  to  be  enabled.  Any  other  meaning  of  this  value  or  any  other  non-zero  value  written  by  the 
host into this register before issuing this command may differ from device to device. 
 
8.2.34.3         Smart enable operations (D8h)
 
 
 
This  command  enables  all  SMART  capabilities  within  the  device.  Prior  to  receipt  of  this  command  SMART 
data  are  neither  monitored  nor  saved  by the  device.  The  state  of  SMART  (either  enabled  or  disabled)  shall  be 
preserved  by the  device  across  power  cycles.  Once  enabled,  the  receipt  of  subsequent  SMART  ENABLE 
OPERATIONS commands shall not affect any SMART data or functions. 
 
8.2.34.4         Smart execute off-line immediate (D4h)
 
 
 
This  command  causes  the  device  to immediately  initiate  the  activities  that  collect  SMART  data  in  an  off-line 
mode and then save this data to the device’s non-volatile memory. 
 
During execution of its off-line activities the device shall not set BSY nor clear DRDY. 
 
If the device is in the process of performing its set of off-line data collection activities  (as a result of receiving a 
SMART  EXECUTE  OFF-LINE  IMMEDIATE  command  from  the  host),  and  is  interrupted  by any  new 
command  from  the  host  except  a SMART  DISABLE  OPERATIONS,  SMART  EXECUTE  OFF-LINE 
IMMEDIATE,  or  STANDBY  IMMEDIATE  command,  the  device  shall  suspend  or  abort  its  off-line  data 
collection  activities  and  service  the  host  within  two  seconds  after  receipt  of  the  new  command.   After 
servicing  the  interrupting  command  from  host  the  device  may  immediately  re-initiate  or  resume  its  off-line 
data collection activities without any additional commands from host 
 
If  the  device  is  in the  process  of  performing  its  off-line  data  collection  activities  and  is  interrupted  by a 
STANDBY   IMMEDIATE  command   from  the  host,  the  device  shall  suspend  or  abort  its  off-line  data 
collection  activities,  and  service  the  host  within  two  seconds  after  receipt  of  the  command.  After  receiving  a 
new  command  that  causes  the  device  to  exit  a  power  saving  mode,  the  device  shall  initiate  or  resume  off-line 
data  collection  activities  without  any additional  commands  from  the  host  unless  the  device  aborted  these 
activities. 
 
If  the  device  is  in  the  process  of  performing  its  off-line  data  collection  activities  and  is  interrupted  by  a 
SMART  DISABLE  OPERATIONS  command  from  the  host,  the  device  shall  suspend  or  abort  its  off-line 
data  collection  activities  and  service  the  host  within  two  seconds  after  receipt  of  the  command.  Upon  receipt 
of  the  next  SMART  ENABLE  OPERATIONS  command  the  device  may,  after  the  next  vendor  specified 
event,  either  re-initiate  its  off-line  data  collection  activities  or  resume  those  activities  from  where  they  had 
been previously suspended. 
 
If  the  device  is  in  the  process  of  performing  its  off-line  data  collection  activities  and  is  interrupted  by  a 
SMART  EXECUTE  OFF-LINE  IMMEDIATE  command  from  the  host,  the  device  shall  abort  its  off-line 
data  collection  activities  and  service  the  host  within  two  seconds  after  receipt  of  the  command.  The  device 
shall then  re-initiate  its  off-line  data  collection  activities  in  response  to  the  new  EXECUTE  OFF-LINE 
IMMEDIATE command.